Skip to content
Water Cooled Load Banks WC — ZENITHSUN
WCSLRB Water Cooled Load Banks

Water Cooled Load Banks ZENITHSUN WC

ZENITHSUNManufacturer: ZENITHSUN

SLRB water-cooled load banks built on water-cooled resistors: 3 kW – 5 MW, 5–1,000 V AC or DC, 0.1–15,000 A. Cooled by flowing tap water, distilled water or other liquid — no deionized-water costs; for the same power the cabinet is lower than an air-cooled one: 50 kW — 700 × 650 × 800 mm versus 680 × 680 × 1,200 mm. Cooling system, pump, tank, cooling tower and piping available on request. RS232/RS485, short-circuit, overload and over-temperature protection. Examples include 400 kW / 1 kV, 770 kW in stainless steel and 96 kW / 400 V DC.

Specifications

Power range
3 kW – 5 MW
Voltage
5–1,000 V AC/DC
Current range
0.1–15,000 A
Coolant
tap or distilled water, other liquid; no deionization required
Optional equipment
cooling system, pump, tank, cooling tower, piping, cables
Control and protection
RS232/RS485 for PC; short circuit, over-current, over-voltage, over-temperature, alarm
Dimensions (examples)
50 kW — 700 × 650 × 800 mm; 2 MW — 2,400 × 1,800 × 2,000 mm

Applications

  • Generator set load testing
  • EV charging station testing
  • Battery discharge testing
  • Burn-in of telecom equipment, UPS and DC/DC converters
  • Water-cooled braking resistor banks

We will select the right size for your task and prepare a quotation under a direct SDS contract.